BACK TO LAB // solar array

Solar array desk.

A photovoltaic array running the real single-diode cell model. Irradiance scales the photocurrent, temperature drops the voltage, and the maximum-power-point shifts with both, so a hot bright panel makes less than its rating. Scrub a real irradiance day, push the array into the heat, and watch the MPP tracker chase the knee. Then size the inverter, let the glass get dirty, and follow every kilowatt down the loss waterfall to the grid.

PANEL FIELD TRACKING

Live tracker field. The sun follows real solar geometry for the scrubbed hour, haze follows the irradiance deficit against clear sky, and the amber DC pulses to the inverter scale with output. Scrub past dusk to stow the field under stars. Switch to 2D for the I-V / P-V curve.

PLANT DAY · Skåne (SE4) · drag to scrub 1.89 MWh AC
AC LIMIT 1180 kW1274kW308W/m²00:0006:0012:0018:0023:00 UTC
AC ENERGY
1.89MWh
PEAK
421kW @ 12:00
SPECIFIC YIELD
1.28kWh/kWp
PERF RATIO
94%
CAP FACTOR
6.7%
CLIPPED
0kWh
INSOLATION
1.37kWh/m²
DAYLIGHT
8.7h · 06:47–15:29 UTC
CLEARNESS
89% of clear sky

Skåne (SE4) · live 2026-11-03 · 12:00 UTC 293 W/m² · 9.4 °C ambient

PLANT ADVISOR
  • MPPT MPP tracking captures 2% more than holding the STC voltage. ▸ The knee sits at 34.8 V now, not the rated 32.8 V. The controller must chase it.
PLANT READOUT
AC POWER 421kW of 1180 kW inverter
DC POWER 432kW 88 W per module
EFFICIENCY 18.3% performance 97%
V · I 35V 2.5A Voc 40.3 · Isc 2.8
CELL TEMP 19°C +9 °C over ambient
FILL FACTOR 79% Pmpp / (Voc × Isc)
INVERTER 97.5% 37% load
SUN 18° S 102% of clear sky
ARRAY 1475kWp 5000 × 295 W
LOSS WATERFALL
Nameplate at 293 W/m² 432 kW
Low light −2 kW 0.4%
Cell temperature +10 kW 2.3%
Off MPP 0 kW 0.0%
Soiling −9 kW 2.0%
Inverter −11 kW 2.5%
Clipping 0 kW 0.0%
AC to grid 421 kW